TIBCO Nimbus 10.4 Hotfix 04 is now available (V 10.4.0.624)

TIBCO Nimbus 10.4 Hotfix 04 is now available (V 10.4.0.624)

book

Article ID: KB0101129

calendar_today

Updated On:

Products Versions
TIBCO Nimbus 10.4.x

Description

This notice is to inform you that a hotfix for TIBCO Nimbus V 10.4.0 has been released.  Hotfix 04 (10-4-0-624)

Please see details attached for information on fixes included, and installation instructions

This hotfix can be accessed by maintained on premise customers and can be downloaded from https://support.tibco.com 

If you are an existing TIBCO Nimbus Cloud Service customer we will contact you to plan an upgrade to this version.

If you have any questions relating to this, please raise a case to the TIBCO Support team via https://support.tibco.com and we will be pleased to help you

Environment

TIBCO Nimbus

Resolution

Closed Issues in 10.4.0.624_HF-004

NIMW-12972
Summary: An error occurs when running the Web Logs utility if a Secure Repository is being used and the user does not have read/write access rights to the Process Repository.

NIMW-13015
Summary: In the web, you are not able to zoom in or out the classic process diagrams on different devices with different screen sizes and resolutions.

NIMW-13052
Summary: Although Contributor users do not have the right to edit maps or diagrams, they are able to perform copy and move operations by using the Diagram Explorer.

NIMW-13115
Summary: On an Android touch device, the panning operation on a classic diagram doesn't always work as expected.

NIMW-13126
Summary: On screens with smaller resolution or on tablets in landscape orientation, you are not able to close the What's New dialog box.

NIMW-13127
Summary: On a touch device, you are not able to resize the Diagram Explorer.

NIMW-13145
Summary: The operation to migrate from version 10.3.0 to version 10.4.0 ensures that all statement sets have a unique GUID. However, this operation might fail if there are three or more statement sets having GUIDs that are not unique.

NIMW-13151
Summary: The state or size of the Diagram Explorer does not persist if you refresh the page.

Affected Files for 10.4.0.624_HF-004

Due to the number of files affected by this hotfix it is recommended that a
re-install of the Author Client, Web Server, and Batch Server is performed.
 

Issue/Introduction

TIBCO Nimbus 10.4 Hotfix 04 is now available (V 10.4.0.624)

Additional Information

NIMW-12963

Attachments