Products | Versions |
---|---|
TIBCO Substation ES | 2.14 |
Please download the Hotfix from the TIBCO Support Customer Portal Web UI using their username and password for the TIBCO Support Web page. Once logged on you can find the Hotfix under the Download Menu :
AvailableDownloads/Mainframe/Substation/2.14.0/hotfix-04
Defect corrections: RED-766 - Critical Storage for data stream transmit buffer is not freed at the end of CICS #RED transactions. This does not affect regions that mainly have long running #RED transactions. The result would be that CICS would eventually exhaust usable storage in the EDSA area. This has been fixed. RED-765 - Informational Missing error text for SXX8312 has now been updated. SESS-2165 - High When Substation is running with IMS, an incorrectly-coded call to a message-issuing routine resulted in an S0C4 abend. This has been fixed. ================================================================================ Hotfix 03 --------- SSES-2161 - High #RED tasks in CICS do not gracefully come down during shutdown. During CICS shutdown #RED transaction(s) do not respond to the PLT SXXOSHUT shutdown request(s). #RED transactions are forced to abend during shutdown. This has been fixed. SSES-2160 - Critical SXXO#RED messages from BPool addressability 31/64 bit. Previously if the interface values were not set correctly, #RED may terminate unexpectedly. Auto-detect now been correctly enabled and the issue has been resolved. SSES-2159 - Critical The Substation RED interface messages in BPool addressability 31/64 bit. Previously if the interface values were not set correctly, the Substation Async/Triggers threads may terminate unexpectedly. Auto-detect now been correctly enabled and the issue has been resolved. RED-762 and RED-756 - Critical Test for expired messages is incorrect and Substation ES reports 7900 and 7901 errors. Modules SXXAX625, SXXAX221 and SXXAX222 have been changed to correct the expiry of messages in 31bit and 64bit buffer pools. This issue has now been resolved. RED-761 - Critical SXXAHUB abends with a S0C3 due to errors when reading parm file. When the Mainframe HUB starts up, it reads the parameters from DDNAME TIBPARM and when this operation fails a S0C3 is issued sometimes with fatal results when incorrect names are specified. This issue has now been resolved. RED-755 - Critical Module SXXAX820 will abend with S0C4 on certain API Leave requests. This issue has now been resolved. RED-754 - Critical SXX8137E error occurs even when buffer pool is not full. This issue has now been resolved. RED-753 - Critical Message Information Block (MIB) was overlaid during Send-with-Reply requests. This caused message SXX7950E with a header length of zero to be displayed. This issue has now been resolved. RED-752 - High Recovery module SXXARCV abends with a S0C1 during application or Substation Abends. This issue has now been resolved. RED-749 - Normal If message expiry time has not been specified, RED currently uses a value of 30 seconds. This change will take the specified timeout value and add 5 seconds for cross-memory and 10 seconds for XCF. SSES-2148 - High Remove Mainframe HUB requirement when using the EXCI interface. This dependency has been removed for v2.14.x SSES-2150 - Critical Under stress the Event List creates duplicate entries and message SXG2936W repeatedly reports incorrect values. This issue has now been resolved. SSES-2152 - Normal Message SXG1891I has been changed to show the RED trigger service name and more. When the trigger service trace level is set to a value higher than zero this message is displayed. ================================================================================ Hotfix 02 --------- SSES-2147 - High Logging to disk (VSAM) functions and the Wrap feature didn't work. This issue has now been resolved. Just a reminder the DISK functions will be deprecated in release 3.0.0. RED-751 - Critical Storage allocated increases for long-running applications. This issue has now been resolved. RED-747 - Critical Incorrect high-water mark of used buffer pool pages. Module SXXAX625 now calculates the number of target buffers currently being used correctly. Resolved. RED-746 Message SXX8810E shows reason code as zero. This issue has been fixed and a valid reason code is displayed ================================================================================ Hotfix 01 --------- SSES-2111 - High When doing Request/Reply using containers and the reply requires more than 20 containers, #RED abends in CICS. #RED now allows now for 127 containers on reply. Corrected and fixed. SSES-2106 - Critical Function Obtain_ErrInfo abends on 0C4. Corrected and fixed. SSES-2095 - High UoW updates for improved stress reporting and handling. Changed messages SXG2131I and SXG2133W to include the current UoW allocation. SSES-2087 - CICS Added new parameter <CorId (N,Y)> to SXC3I032 (SXT6) sample program. SSES-2080 - ESB Critical Added new parameter for a RVDQ scheduler to set the completion time for task scheduled for a worker. The parameter is RVDQ-SETCOMPTIME. Valid values are 0 - 30 seconds. Zero (0) is the default. SSES-2075 - Critical Substation ES now allows a trigger service using containers to include a correlation ID container, where the output message will be sent by Substation ES with JMSCorrelationID property for EMS, or tibss-CorrelationId as a field for RV. SSES-2071 - Critical Fixed Substation ES to allow Recipes with Method of Reply = 0 | 1 to be able to forward the Correlation ID and the Service REPLY-TO value as separate container fields to the BES application.