Products | Versions |
---|---|
TIBCO Enterprise Message Service | 8.4.0 |
This hotfix can be downloaded from the SFDC Customer Portal Web User Interface using your username and password for the TIBCO Support Web. Once logged on you can find the hotfix under the Downloads Menu:
"AvailableDownloads/Messaging/EMS/8.4.0/Hotfix-2. Please read the Readme file for Instruction before to apply the hotfix.
Closed Issues in 8.4.0_HF-002 (This Release)
EMS-7323
Fixed a defect in which the reconnection of a client after a fault-tolerance
failover could cause another connection that was given the same ID in the
meantime to be terminated. This could occur under rare circumstances and
manifest in the server log as "reconnect detected: replacing active
connection". This defect affected Release 8.4.0.
EMS-7296
Fixed a defect in which slow operations could interfere with the
heartbeat protocol between the EMS server and clients, resulting in
client disconnect. This defect affected Releases 8.3.0 and 8.4.0.