Products | Versions |
---|---|
TIBCO Managed File Transfer Platform Server for zOS | 7.2.0 |
Hotfix CZ02035 can be downloaded from TIBCO Support Portal (https://support.tibco.com).
You will need to provide your TIBCO Support Portal credentials. Once logged in you can download the hotfix by selecting the “Downloads” -> “Hotfixes” option. Then go to “/AvailableDownloads/MFT/PlatformServer/zOS/7.2.0/” to download the hotfix.
The .zip file has the Readme file inside. Please unzip the file and review the Readme file for instructions on how to apply the hotfix.
PreReq HotFix: CZ02021
Supersedes: CZ02028
Note: Hotfix CZ02021 MUST be applied before applying this hotfix.
Problem Description:
This hotfix resolves defects that have been fixed since hotfix CZ02028
was released.
Defects fixed in CZ02035:
PSZ-281 %YDATE and %YGDATE Script variables can return an incorrect date
PSZ-280 Abend 0E0 received in module OSIAINT0 due to corrupted AR6
PSZ-278 Transfer fails with error "PGTM7344E" after altering the start
time of a transfer through the ISPF interface
PSZ-277 After upgrading to z/OS 2.2, a 0E0 abend occurred in FUSASNAR+6232
due to a corrupted AR15
PSZ-276 Script interface received error: "PGTS4204E OSIUC000 Parameter
error on SYSIN record" after applying hotfix CZ02028
Defects fixed in CZ02028:
PSZ-274 After upgrading to z/OS 2.2, intermittent abends occurred in
module OSINBDAP due to corrupted AR15
PSZ-272 Two modules incorrectly used 24 bit storage; changed to use
31 bit storage.
PSZ-271 Highly utilized systems received message:
PGTS0023I LOG Slot full: Overwriting previous message in log file
In=xxxxxxxx Out=yyyyyyyy
PSZ-270 Created scripting variables for yesterday's date. The following
new script variables were created and reflect one day prior to
the current date at the time of execution.
: %YDATE CCYYDDD
: %YGDATE CCYYMMDD
: %YGDATE1 1YYMMDD
: %YGDATE2 YYYYDDMM
: %YGDATE3 MMDDYYYY
: %YGDATE4 DDMMYYYY
PSZ-267 PPA SUBMIT fails due to Dynamic Allocation failure allocating
source JCL dataset.
Note: Additional debugging messages were added to identify the
job holding the ENQ on the source JCL dataset
PSZ-265 When executing a directory RECEIVE with an IPName > 24 characters,
the transfer fails with error:
PGTF3213E Receive Directory Failed: Network error on ALLOC
PSZ-262 Received intermittent abend 0E0 in OSIADIR0+15F0 when executing
Directory Transfer
PSZ-261 When a Job or DNI uses TRANS_TYPE=JOB, the PPA %LFILE token is not
resolved correctly
Defects fixed in CZ02025:
PSZ-260 Unable to delete or update files when the file expiration date is
set to PERMANENT or to a future date
Added the following GLOBAL parameters:
UNEXPIRED_DISK_FILE_DELETE={YES|NO}
Defines whether MFT will allow Receive Transfers defined with
a disposition of DNEW to delete a file that has not expired:
YES: Allow MFT to delete unexpired files when DISP=DNEW
NO: Do not allow MFT to delete unexpired files when DISP=DNEW
No is the default value
UNEXPIRED_DISK_FILE_UPDATE={YES|NO}
Defines whether MFT will allow Receive Transfers to update
a file that has not expired:
YES: Allow MFT to update unexpired files
NO: Do not allow MFT to update unexpired files
No is the default value
Note: If this parameter is set to YES, message IEC507D will
be displayed and will wait for an operator response.
Until the operator responds, subsequent dynamic allocations
will hang. We suggest not setting this parameter to YES
unless you have defined an automatic response to the IEC507D
message.
PSZ-259 Receive error when following Process Statements are defined:
FILE_EXPDT=1999365 or FILE_EXPDT=99365
FILE_EXPDT=1999366 or FILE_EXPDT=99366
PGTB4102E Invalid parameter value in next record
PSZ-258 Command Center detects Protocol Error when SSL Audit Poll or
Collection request returns 0 records
PSZ-257 When GLOBAL ENFORCE_SECURITY_POLICY set to FIPS140, the MFT STC
displays message PGTS1393E and terminates
A new value was added to parameter to ENFORCE_SECURITY_POLICY:
ENFORCE_SECURITY_POLICY=TLSFIPS
This value ensures that all SSL/TLS connections are executed
using FIPS 140 protocols and ciphers, but will not require the
entire STC to execute in FIPS 140 mode.
PSZ-256 When using the ISPF panels and specifying an IPV4 IP Address as
the Remote System name, the connection fails with a connection
error to IP Address 0.0.0.0