Description:
Product Name : TIBCO iProcess Engine (SQL)
Release Version : 11.0.2-Hotfix04
Release Date : August 2009
=============================================================
This hotfix applies to TIBCO iProcess Engine version 11.0.2 running
on the following platform and database:
Windows 2000/2003 with SQL Server 2000/2005
TIBCO iProcess Objects Server 11.0.2-Hotfix01 is included as part of
this distribution. See the separate readme.txt attached for more details.
=============================================================
Closed Issues in 11.0.2-Hotfix04
Defect Id: 41143
If IAPJMS is configured and the iProcess Engine cannot connect to the
EMS server, the BG processes are slowed and may hang.
Corrected.
The IAPJMS process returns a new code "04" to the BG if the connection
to EMS is in failover when BG needs a reply. IAPJMS messages are then
ignored until the connection is restored. An error message is written
to sw_error, in the following format:
2009/08/18 17:36:58
(iapjms:::2::com.staffware.core.iapjms.library.iapjmsserver.
GenericJMSProducer::261):1998-IAPJMS Message ignored. Reason: JMS
connection is in failover
A new process attribute IAPJMS_TESTCON_INTERVAL has been added to set
the interval for testing the connection to EMS. This value is
specified in seconds; it should be in the range 1 to 30 and defaults
to 5 if not specified.
You can change this value using the following command:
swadm set_attribute 0 ALL 0 IAPJMS_TESTCON_INTERVAL <value>
See the TIBCO iProcess Engine Administrator's Guide for more
information on using the SWDIR\util\swadm utility to set attributes.
=============================================================