Products | Versions |
---|---|
TIBCO iProcess Analytics Export | - |
Not Applicable | - |
Description:
Product Name : TIBCO iProcess Analytics Export for Windows
Release Version : 10.6.0.2
Release Date : May 2008
========================================================
* Bug Fixes in this HOTFIX Release:
HOTFIX-2
* MR 33271
TIBCO iProcess Analytics Export hard codes all date filters to a
DMY format rather than using the same format for which the iProcess
Engine has been configured. If the iProcess Engine uses a different
format, the export fails with the following error message in the
log: "-2147221392:SWServer Error: Error in expression syntax".
This error number resolves to -112.
Corrected. Now every time iProcess Analytics Export logs into
a node to perform an export, it will use the date format, as well
as the date and time separator, as specified on the engine. Export
compares the date order specified on the engine (which is specified
in the SWDIR\etc\staffpms file) against the six possible combinations
of ‘d’, ‘m’ and ‘y’, that is, dmy, dym, mdy, myd, ydm, and ymd. If it
is not one of these, an error is logged and the date order used will
be “dmy”.
The date and time format is also now logged on every export.
* MR 35543
Date fields on the TIBCO iProcess Analytics Export main setup screen
do not currently accommodate all of the formats needed. They
currently only support MM/DD/YYYY, DD/MM/YYYY, and DD.MM.YYYY (which
are selectable from the Options dialog).
Corrected. There are now nine supported formats for date fields.
They are: MM/DD/YYYY
DD/MM/YYYY
YYYY/MM/DD
MM.DD.YYYY
DD.MM.YYYY
YYYY.MM.DD
MM-DD-YYYY
DD-MM-YYYY
YYYY-MM-DD
Note - The date format that is selectable on the Export Options dialog
only changes how the starting and ending dates in the main Export setup
screen are displayed and how the dates are logged. This does NOT
change the date/time format that is used within the filter portion of
the message sent to the iProcess Objects Server and the iProcess Engine.
The date/time format that is sent in the filter to the iProcess Objects
Server and the iProcess Engine is determined by the SWDIR\etc\staffpms
file for each iProcess Engine that Export contacts.
This also means that the date formats used in the Export setup screen
are the same for every iProcess Objects Server that is configured in
Export. However, since the date/time format that is sent in the filter
to any particular iProcess Objects Server is determined by the staffpms
file for that particular node, the date/time format could be different
for every iProcess Objects Server where an export is being done.
========================================================
NOTE: See attached readme document for installation instructions and issues resolved in previous hotfix releases.
========================================================
The TIBCO iProcess Analytics Export for Windows 10.6.0 HotFix 02 can be downloaded from our support-ftp.tibco.com. You will be able to download by clicking on the link below after you provide your TIBCO Support Web username and password in the url:
ftp://username:password@support-ftp.tibco.com
Directory path:
available_downloads/StaffwareProcessSuite/iProcess/AnalyticsExport/10.6.0/hotfix-02