Hotfix 2 for TIBCO Adapter for PeopleSoft 5.2.0 is now available for windows and all the supported unix platforms

Hotfix 2 for TIBCO Adapter for PeopleSoft 5.2.0 is now available for windows and all the supported unix platforms

book

Article ID: KB0106163

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for PeopleSoft -
Not Applicable -

Description

Description:
Hotfix 2 for TIBCO Adapter for PeopleSoft 5.2.0 is now available for windows and all the supported unix platforms.

This HotFix is cumulative of prior hot fixes for this version. Listed below is a summary of updates included in HotFix 2. Please refer to the attached Readme for additional details.

Defects fixed in Hotfix 2:
-------------------------
Defect Id: 1-8IAYN3
==================
Defect Description: When configuring the adapter, you could not configure the HTTP port number using global variables in the Adapter Services tab.

Resolution:This has been fixed. Now,the HTTP port number can be configured using global variables in the Adapter Services tab.

Defect Id:1-8IO8WK
===================
Defect Description:When configuring the Message Publication Service, you could not configure the specified Message Subject in the Advanced tab using a global variable that was created in the global variable group.

Resolution:This has been fixed.Now, the message subject can be specified in Advanced tab of Message Publication Service using a global variable that was created in a global variable group.

Defect Id:1-7Y6YD6
==================
Defect Description:You could not set the polling interval for the Publisher as a global variable.

Resolution:This has been fixed.Now,the polling interval for the Publisher can be configured as a global variable.

Defect Id:1-7X3VPT
=================
Defect Description:You could not set the Polling interval to a value more than 65535 milliseconds.

Resolution:This has been fixed.Now,polling interval can be set to a value more than 65535 milliseconds.

Defect Id:1-8IYDQD
==================
Defect Description:When using PT 8.20, the adapter did not inflate the message payload when Message Publishing used French Characters.

Resolution:This has been fixed.Now, the adapter inflates the message payload when publishing a message using French characters.

Defect Id:1-8IYQRK
==================
Defect Description:When JMS was the chosen transport type, the specified queue name was not reflected in the destination field in the endpoint reference tab.

Resolution:This has been fixed.Now when the transport is chosen as JMS,the queue name gets reflected in the destination field in the end point reference tab.

Defect Id:1-8K0CUS
==================
Defect Description:The adapter did not support encrypted passwords generated by  PSCipher in TIBCOTARGET connectors.

Resolution:This has been fixed.Now, the adapter supports encrypted passwords generated using PSCipher in TIBCOTARGET connectors.

Defect Id:1-8NYWKT
=================
Defect Description:During publication using Integration Broker, the adapter skipped every other
child node when transmitting to TIBCO BusinessWorks.

Resolution:This has been fixed.Now, the adapter publishes the entire message structure including all the child nodes during publication using Integration Broker.

The following defects fixed in PeopleSoft Adapter 5.2.0 hotfix1 are rolled in this 5.2.0 hotfix 2:
-------------------------------------------------------------------------------------------------
Defect Id assigned: 1-82J434
=============================
Defect description: When PeopleSoft DTA connected to multiple PeopleSoft servers, it did not fetch the correct Component Interface (CI).

Resolution:This has been fixed. Now, the adapter fetches the correct Component Interface(CI) when the PeopleSoft DTA is connected to multiple PeopleSoft servers.

Defect Id assigned:1-82J42L
===========================
Defect description:The Design-Time Connection tab did not let users specify Global
Variables for the Port field other than the default Global Variable.

Resolution:This has been fixed.Now, the Design-Time Connection tab allows users to specify Global Variables for the Port field other than the default Global Variable.

Defect Id assigned:1-80XGVM
===========================
Defect description:PeopleSoft 8.1.x projects could not fetch numeric fields for all
services configured over Component Interface (CI).

Resolution:This has been fixed.Now,PeopleSoft 8.1.x projects can fetch numeric fields for all services configured over Component Interface (CI).

This hotfix can be downloaded from the TIBCO Product Support ftp server, ftp://support-ftp.tibco.com/, using your username and password for the TIBCO Support Web.  Once logged on you can find the hot fix under:

available_downloads/ActiveEnterprise/Adapters/PeopleSoft/5.2.0/hotfix-2/

Please contact TIBCO Support if you have any problems finding or downloading this hotfix.

Environment

Product: TIBCO Adapter for PeopleSoft Version: 5.2.0 OS: --------------------

Issue/Introduction

Hotfix 2 for TIBCO Adapter for PeopleSoft 5.2.0 is now available for windows and all the supported unix platforms

Attachments