Products | Versions |
---|---|
TIBCO iProcess Technology Plug-ins | 11.9.0 |
===============================================================================
Product Name : TIBCO iProcess(R) Technology Plug-ins
Release Version: 11.9.0_HF‐007
Release Date : May 2025
===============================================================================
Installation
1. Shut down TIBCO iProcess Engine.
2. Back up the following existing files to a safe location that should be
outside of the $SWDIR directory:
- $SWDIR/lib/EAI_JAVA_i11_9_0_6.ear
- $SWDIR/eaijava/libs/repository/plugin/eaijava_runtime_library.jar
3. Copy the eaijava.ear file from the given package to the following
path and leaving the permissions and ownership as they are.
- $SWDIR/lib/EAI_JAVA_i11_9_0_7.ear
4. Copy the eaijava_runtime_library.jar file from the given package to the
following path and leaving the permissions and ownership as they are.
- $SWDIR/eaijava/libs/repository/plugin/eaijava_runtime_library.jar
5. Source the iProcess Engine environment and run below commands:
sweaireg UNREG EAIJAVA -y
sweaireg REG EAIJAVA -l $SWDIR/lib/EAI_JAVA_i11_9_0_7.ear -i $SWDIR/eaijava
fixperms -R $SWDIR/lib
6. Restart TIBCO iProcess Engine.
===============================================================================
Affected Files for 11.9.0_HF‐007 (This Release)
- eaijava.ear
- eaijava_runtime_library.jar
===============================================================================
Closed Issue in 11.9.0_HF‐007 (This Release)
IPTP-1247
EAI BW step fails to open when iProcess Engine is configured with high volume
of data in the destination endpoints.
Due to this reason, eventually workspace client crashes.
Corrected
This hotfix works only when TIBCO iProcess Engine 11.9.1.1 is applied in the environment.
This hotfix applies to The TIBCO iProcess(R) Technology Plug-ins 11.9.0 running on
the below platforms:
CentOS
7.6, 7.x, and 8.0 64-bit on x86-64
Oracle Linux
7.6, 7.x, 8.0, and 8.x 64-bit on x86-64
Red Hat Enterprise Linux Server
7.6, 7.x, 8.0, and 8.x 64-bit on x86-64
SUSE Linux Enterprise Server
12 SP2, 12.x, 15, and 15.x 64-bit on x86-64
The hotfix can be downloaded from the TIBCO Support Customer Portal Web UI,
using your username and password for the TIBCO Support Web.
Once logged on the hotfix can be found under the Downloads Menu:
AvailableDownloads/iProcess/TechnologyPlugins/11.9.0/hotfix007
TIBCO iProcess(R) Technology Plug-ins 11.9.0 HotFix 007 is available
TIB_ip-tech-pi_11.9.0_HF-007_readme.txt