Spotfire Node Manager services fail to start due to potential conflict with Trend Micro Antivirus scans
book
Article ID: KB0070024
calendar_today
Updated On:
Products
Versions
Spotfire Server
All supported versions
Description
Spotfire administrators may encounter challenges starting Node Manager services such as Web Player and Automation Services, or keeping them up and running, because of a potential conflict with Trend Micro Antivirus scans.
Snip from the Logs:
mm/dd/yyyy hh:mm:ss - 3e56a733-0de7-4fe7-88b6-a2cdf3f03311 Failed to start worker. System.ArgumentException: Illegal characters in path. at System.Security.Permissions.FileIOPermission.EmulateFileIOPermissionChecks(String fullPath) at System.Security.Permissions.FileIOPermission.QuickDemand(FileIOPermissionAccess access, String fullPath, Boolean checkForDuplicates, Boolean needFullPath) at System.IO.Path.GetFullPath(String path)
Issue/Introduction
This article suggests a remedy for Spotfire Node Manager services that fail to start due to potential conflict with Trend Micro Antivirus scans.
Environment
All supported operating systems
Resolution
As a workaround, it is recommended to exclude the Spotfire installation folder and sub-folders from Trend Micro Antivirus scans. A potential permanent fix for this issue is being investigated.