View suppressed message (FOC1500) in the EDAPRINT file
book
Article ID: KB0070722
calendar_today
Updated On:
Products
Versions
ibi WebFOCUS
8207.28.13 and Above
Description
How to view following messages in WebFOCUS EDAPRINT file?
(FOC1500) *** 5 messages suppressed ***
Resolution
The EMGSRV parameter controls the error message routing. To show all the suppressed error messages follow the below steps: 1) From Webfocus Home > Go to the Management Center. 2) In Server Administration > Select 'Server workspace'. 3) Click on Settings, then Focus Sets and Info. 4) Go to Core Engine Settings > Select 'Service Area' : 'Error / Warning Control' - Next. 5) Select EMGSRV: 'EDAPRINT/ON - Route to EDAPRINT and normal output' - Save.
If one still see some of your error messages. Then those are still suppressed because the Maximum number of identical error messages is set as 10 in server preferences setting. To increase the value there, follow the below steps: 1) In Server Administration > Click 'Server Preferences' . 2) In the Reporting option, increase the 'Maximum number of identical error messages' from 10 to 100 or 50. - Update[Save].
Issue/Introduction
View the suppressed error messages in the edaprint log
Additional Information
https://docs.tibco.com/pub/wf-rs/8207.28.14/doc/pdf/TIB_wf-rs_8207.28.0_administration.pdf?id=1
Topic: Controlling Error Message Processing With the EMGSRV and EMGLIMIT Parameters
Page: 596