TIBCO Spotfire Webplayer service installation may fail post upgrade to 11.5.0 and above versions

TIBCO Spotfire Webplayer service installation may fail post upgrade to 11.5.0 and above versions

book

Article ID: KB0072635

calendar_today

Updated On:

Products Versions
Spotfire Server 11.5.0 and higher

Description

You may notice webplayer service failure in admin console UI after upgrading to 11.5.0 and above versions. The following errors are seen in nm.log:

INFO 2021-11-09T14:32:11,611-0500 [b36f972a-5a2f-40a6-bb1d-f7ba2d654a72] nodemanager.control.ServiceConfigCommandHandler: Announcing service instance: 478f78ba-7db0-4984-9249-00266603535d status STARTING
INFO 2021-11-09T14:32:11,611-0500 [b36f972a-5a2f-40a6-bb1d-f7ba2d654a72] nodemanager.control.ServiceConfigCommandHandler: Announcing installation: Web Player 11.5.0
ERROR 2021-11-09T14:32:12,080-0500 [] server.nodemanager.ServiceMonitor: (FAILED) Process 478f78ba-7db0-4984-9249-00266603535d notified. Next Status STARTING
INFO 2021-11-09T14:32:12,080-0500 [] server.nodemanager.ServiceMonitor: Notifying about service: 478f78ba-7db0-4984-9249-00266603535d in state FAILED/STARTING. Last status message: Exited while initializing. Recent Logs: 11/09/2021 14:32:12 -  TIBCO Spotfire 11.5 and later requires .NET 4.8. Install Microsoft .NET Framework 4.8 and try again.

INFO 2021-11-09T14:32:12,080-0500 [] nodemanager.service.AbstractServiceManager: Determining if the service 478f78ba-7db0-4984-9249-00266603535d should restart (attempt #1, startedCount=0). Last exit code was ERRORSTARTUP
INFO 2021-11-09T14:32:12,080-0500 [] service.strategy.ServiceStrategy: Service 478f78ba-7db0-4984-9249-00266603535d will not be restarted. It has been 0 seconds since startup which is less than the threshold of 30 seconds
INFO 2021-11-09T14:32:12,080-0500 [] nodemanager.service.AbstractServiceManager: Service 478f78ba-7db0-4984-9249-00266603535d should not be restarted: Last exit message: ERRORSTARTUP 
ERROR 2021-11-09T14:32:12,080-0500 [] server.nodemanager.ServiceMonitor: The service [WEB_PLAYER]:478f78ba-7db0-4984-9249-00266603535d exited and will not be restarted.
INFO 2021-11-09T14:32:12,830-0500 [] nodemanager.remote.PropertiesManagerMonitor: Received ENTRY_MODIFY event for C:\tibco\tsnm\11.5.0\nm\config\config.json
INFO 2021-11-09T14:32:12,877-0500 [6d1f0926-5918-4ad7-8801-d7827438354b] nodemanager.control.ServiceManipulator: All services [478f78ba-7db0-4984-9249-00266603535d] have reported status beyond STARTING
INFO 2021-11-09T14:32:12,877-0500 [3b0176c4-476f-4b6a-9bfd-4c883a87da02] nodemanager.control.ServiceConfigCommandHandler: Received IDENTIFY_SERVICES from Node [serverId=ddae5576-9593-40c4-a1e5-8823e6767421, serverName=na1devsptpc201.dev.tibco.com, port=9443, siteID=5c2c7b84-e1f4-4187-9799-85a2a48f0ebc]. Command GUID: 3b0176c4-476f-4b6a-9bfd-4c883a87da02  Originated by StartServiceCommandHandler
INFO 2021-11-09T14:32:12,877-0500 [3b0176c4-476f-4b6a-9bfd-4c883a87da02] nodemanager.control.ServiceConfigCommandHandler: Announcing to supervisor 2 service configurations
INFO 2021-11-09T14:32:12,877-0500 [3b0176c4-476f-4b6a-9bfd-4c883a87da02] nodemanager.control.ServiceConfigCommandHandler: Announcing service instance: 478f78ba-7db0-4984-9249-00266603535d status FAILED
INFO 2021-11-09T14:32:12,877-0500 [3b0176c4-476f-4b6a-9bfd-4c883a87da02] nodemanager.control.ServiceConfigCommandHandler: Announcing installation: Web Player 11.5.0
WARN 2021-11-09T14:32:12,877-0500 [6d1f0926-5918-4ad7-8801-d7827438354b] nodemanager.control.DeployCommandHandler: Could not startup service based on {"@class":"com.spotfire.server.nodemanager.domain.ServiceInstanceConfiguration","status":"UNCONFIGURED","name":"Web Player","id":"478f78ba-7db0-4984-9249-00266603535d","serviceType":"SERVICE_INSTANCE","host":null,"version":"11.5.0","nextStatus":"STARTING","onStopStatus":"RESTART","startupCommand":"Spotfire.Dxp.Worker.Host.exe -tssUrl $tssUrl$ -baseUrl https://$host$:$port$/$serviceId$/ -enabledCapabilities $enabledCapabilities$ -serviceId $serviceId$ -certificatePath $certificatePath$ -registrationPort $registrationPort$","restartOnStop":true,"startOnStartup":true,"externallyManaged":false,"externallyStarted":false,"serviceManager":"com.spotfire.server.nodemanager.service.WorkerhostServiceManager","configuration":{"centralizedConfigId":"88f2e912-3635-4c7f-acf2-739c15bfdf24","targetFramework":"NETFRAMEWORK","port":"9501","enabledCapabilities":"WEB_PLAYER"},"environment":null,"capabilities":["WEB_PLAYER"],"workingDirectory":"WebWorker-52.0.16415.4853-0beffa33-fe7f-4b57-aaaa-60f610559399","deploymentArea":"191651f9-5e8f-49de-9ef7-43e42fb852b8","bundleVersion":"52.0.16415.4853","replacedById":null,"nodeId":null,"serviceConfigName":null,"versionHash":null,"technicalVersion":null,"lastMessage":null,"serviceURI":"https:/478f78ba-7db0-4984-9249-00266603535d"}
ERROR 2021-11-09T14:32:16,611-0500 [service-478f78ba-7db0-4984-9249-00266603535d-startup] service.monitor.ServiceStatusCallable: Max attempts to check the service 478f78ba-7db0-4984-9249-00266603535d has occurred. Shutting down the service.
INFO 2021-11-09T14:32:16,611-0500 [service-478f78ba-7db0-4984-9249-00266603535d-startup] nodemanager.service.AbstractServiceManager: Service ID 478f78ba-7db0-4984-9249-00266603535d is in a failing state Could not retrieve information from the service. Check that the port is accessible.. Shutdown lock aquired? true
ERROR 2021-11-09T14:32:16,611-0500 [] server.nodemanager.ServiceMonitor: (FAILED) Process 478f78ba-7db0-4984-9249-00266603535d notified. Next Status FAILED
INFO 2021-11-09T14:32:16,611-0500 [] server.nodemanager.ServiceMonitor: Notifying about service: 478f78ba-7db0-4984-9249-00266603535d in state FAILED/FAILED. Last status message: Exited while initializing. Recent Logs: 11/09/2021 14:32:12 -  TIBCO Spotfire 11.5 and later requires .NET 4.8. Install Microsoft .NET Framework 4.8 and try again.

INFO 2021-11-09T14:32:16,611-0500 [] nodemanager.service.AbstractServiceManager: Determining if the service 478f78ba-7db0-4984-9249-00266603535d should restart (attempt #1, startedCount=0). Last exit code was ERRORSTARTUP
INFO 2021-11-09T14:32:16,611-0500 [] service.strategy.ServiceStrategy: Service 478f78ba-7db0-4984-9249-00266603535d will not be restarted. It has been 4 seconds since startup which is less than the threshold of 30 seconds
INFO 2021-11-09T14:32:16,611-0500 [] nodemanager.service.AbstractServiceManager: Service 478f78ba-7db0-4984-9249-00266603535d should not be restarted: Last exit message: ERRORSTARTUP 
INFO 2021-11-09T14:32:16,611-0500 [] nodemanager.service.AbstractServiceManager: Could not find the tool for 478f78ba-7db0-4984-9249-00266603535d (C:\tibco\tsnm\11.5.0\nm\/services\WebWorker-52.0.16415.4853-0beffa33-fe7f-4b57-aaaa-60f610559399/Tools/workershutdown.bat)
INFO 2021-11-09T14:39:12,941-0500 [*Shutdown*] server.nodemanager.NodeManager: Node Manager shutting down...

Resolution

The above entries clearly mentions that TIBCO Spotfire 11.5 and later requires .NET 4.8. Installing Microsoft .NET Framework 4.8 will help resolve the issue.
 

Issue/Introduction

The article provides details as to why TIBCO Spotfire Webplayer service fails to start in UI post upgrade to 11.5.0 and the instructions to solve it.

Additional Information

External: Install Microsoft .NET Framework 4.8 Doc: System Requirements page for TIBCO Spotfire Webplayer