TIBCO® Operational Intelligence Agent fail to start

TIBCO® Operational Intelligence Agent fail to start

book

Article ID: KB0073467

calendar_today

Updated On:

Products Versions
TIBCO Operational Intelligence Agent 3.x

Description

When user try to start Operational Intelligence Agent from location Config_home\tibco\cfgmgmt\oiag\bin gets below error in agent.log file and Agent gets shut down automatically.

<-----
******************************************************************************
    TIBCO OI Agent Version: 3.0.0.V184 Build Date: June 01 2020
******************************************************************************
 ## Tue May 25 18:16:47 IST 2021 ##
ERROR : Fatal Error: Failed to reconnect to HawkTcpDaemon after several reconnects ## Tue May 25 18:18:33 IST 2021 ##
ERROR : Shutting Down... ## Tue May 25 18:18:33 IST 2021 ##
INFO : Agent gracefully shutting down - OI Agent Name:[nandhale-t470]  PID:[19664] ## Tue May 25 18:18:33 IST 2021 ##
----->

 

Issue/Introduction

TIBCO® Operational Intelligence Agent fail to start

Environment

All

Resolution


To solve this issue first start OIConsole then start Operational Intelligence Agent.

OIConsole has the TCP Daemon/ Cluster manager embedded into it. OIconsole will start this TCP Daemon and Operation Agent will connect to this Daemon and start functioning.