Setting Translate Inside Range to False will prevent Engine instances from login even if NAT Translation Range is not used
book
Article ID: KB0075061
calendar_today
Updated On:
Products
Versions
TIBCO DataSynapse GridServer
5.2.x, 6.3.x, 7.0
Description
Engine instances will not be able to login to its Broker(s) if Translate Inside Range to False under Communication page on GridServer Admin UI even if NAT Translation Range setting is not used (default value for this on UI is 0.0.0.0/0). This is as per design as of this writing.
Issue/Introduction
Currently, by design, if set Translate Inside Range to False, this will prevent Engine instances from login even if NAT Translation Range still set to 0.0.0.0/0 (default value)
Environment
ALL
Resolution
Set Translate Inside Range to True (default value) under Communication page on GridServer Admin UI to prevent this issue.