COM.TIBCO.hawk.ami.AmiException: Instrumentation is not enabled for the Process

COM.TIBCO.hawk.ami.AmiException: Instrumentation is not enabled for the Process

book

Article ID: KB0075070

calendar_today

Updated On:

Products Versions
TIBCO Hawk - Container Edition ALL

Description

As error clearly says Instrumentation is not enabled for the BWCE Process.

Issue/Introduction

For Hawk Container, bwce microagent getProcessStats method returns an error COM.TIBCO.hawk.ami.AmiException: Instrumentation is not enabled for the Process

Environment

ALL

Resolution

Application statistics collection can be enabled or disabled from the monitoring dashboard by setting the following property:

Process Instrumentation:
To enable the monitoring of an application running on multiple app container, click the application name and click ON the Process Instrumentation property. Process Instrumentation statistics is collected for all applications.

For More details on App Stats refer below link:
https://docs.tibco.com/pub/bwce/2.3.2/doc/pdf/TIB_bwce_2.3.2_application_monitoring_and_troubleshooting.pdf
Application Monitoring Overview ..> Application Statistics Collection .

Additional Information

https://docs.tibco.com/pub/bwce/2.3.2/doc/pdf/TIB_bwce_2.3.2_application_monitoring_and_troubleshooting.pdf