System/User data source option is greyed out while creating ODBC connection

System/User data source option is greyed out while creating ODBC connection

book

Article ID: KB0075565

calendar_today

Updated On:

Products Versions
Spotfire Analyst All versions

Description

While creating an ODBC connection in Spotfire Analyst, the system and user data source option is greyed out. Below is the reference image:

User-added image

Issue/Introduction

System/User data source option is greyed out while creating ODBC connection

Environment

All Supported OS

Resolution

The system and user data source option are greyed out because there is no user/system DSN that is present/created inside the ODBC Data Source Administrator(32/64).

So firstly create a DSN and open the ODBC connection window again.

Note: There is no need to relaunch the Spotfire Analyst.