While importing the data having DateTime/time column, the milliseconds values are not visible inside Spotfire Analyst

While importing the data having DateTime/time column, the milliseconds values are not visible inside Spotfire Analyst

book

Article ID: KB0075593

calendar_today

Updated On:

Products Versions
Spotfire Analyst All versions

Description

While importing the data having DateTime/time column from Connector or Information link connection, the milliseconds part values are not visible inside Spotfire Analyst.By default, Spotfire neglects the milliseconds value present inside the DateTime column

Example: 10/16/2009 3:25:55:754 PM => 10/16/2009 3:25:55 PM

Environment

All Supported OS

Resolution

To resolve it, custom formatting options present inside the column properties can be used.

Example: M/d/yyyy h:mm:ss:fff

User-added image


Note: 1) 'fff' is used to return the milliseconds part.
          2) TIBCO Spotfire can only show 3 digit value in the decimal part

Issue/Introduction

While importing the data having DateTime/time column, the milliseconds values are not visible inside Spotfire Analyst