Error 322 Error initializing the Message Processor in IE
book
Article ID: KB0078175
calendar_today
Updated On:
Products
Versions
TIBCO Scribe Insight
7.9.1
Description
The TIBCO Scribe Insight alert log is giving the following error:
Error initializing the Message Processor. 322. In IE, check for server certificate revocation has been unchecked
Messages running through a Queue from an XML Source to a CRM Target are taking a very long time to process. For example, it took 3 days for 14K messages to be processed by a simple DTS.
Check Settings On The TIBCO Scribe Insight Server
Stop all five Scribe Windows Services.
Open the Windows Control Panel.
Select Network and Internet.
Select Internet Options.
On the Internet Properties dialog select the Advanced tab.
In the Settings section scroll down to find the Check for publisher's certificate revocation option.
If it is unchecked, check this option, then select Apply and OK.
Restart the five Scribe Windows Services.
If the issue is not resolved, open a case with TIBCO Scribe Support.
Environment
TIBCO Scribe Insight
Issue/Introduction
A setting in the TIBCO Scribe Insight Server's Internet Options is not checked which is causing errors.