Description
Description: When doing an import of an X12, EDIFACT, or TEXT schema into TIBCO Designer, the import operation succeeds but the schema does not appear in Designer. Symptoms: As described above. Cause: In the TIBCO BusinessConnect operations editor for the transaction in question, the root element is not specified or is incorrectly set.
Resolution
Under the Schema tab of the Transaction specification under Administrator>BusinessConnect>Operation Editor, make sure that the "Request Root Element Name" is set to the correct value. This value is a string that usually starts with "T-" as exported from EDISIM.