EDI schemas do not get loaded into Designer when importing from BusinessConnect.

EDI schemas do not get loaded into Designer when importing from BusinessConnect.

book

Article ID: KB0085472

calendar_today

Updated On:

Products Versions
TIBCO BusinessConnect EDI Protocol Powered by Instream -
Not Applicable -

Description

Description:
When doing an import of an X12, EDIFACT, or TEXT schema into TIBCO Designer, the import operation succeeds but the schema does not appear in Designer.
Symptoms:
As described above.
Cause:
In the TIBCO BusinessConnect operations editor for the transaction in question, the root element is not specified or is incorrectly set.

Resolution

Under the Schema tab of the Transaction specification under Administrator>BusinessConnect>Operation Editor, make sure that the "Request Root Element Name" is set to the correct value. This value is a string that usually starts with "T-" as exported from EDISIM.

Issue/Introduction

EDI schemas do not get loaded into Designer when importing from BusinessConnect.

Additional Information

TIBCO BusinessConnect EDI Protocol User's Guide, EDISIM.