Products | Versions |
---|---|
TIBCO Runtime Agent (TRA) | - |
Not Applicable | - |
Resolution:
Description:
===========
The following error is seen when adding EMS Server to Administrator domain using Domainutilitycmd :
*************************************************************************
Validation Failed: Software executable wasnt found in the specified path.
Operation Failed. Please view the log for more details.
*************************************************************************
Environment:
===========
TIBCO Runtime Agent (TRA) 5.x.x
TIBCO Administrator 5.x.x
TIBCO Enterprise Message Service (EMS) 4.x.x / 5.x.x
Symptoms:
========
Domainutilitycmd fails with the following error while trying to add EMS Server to Administrator domain:
Validation Failed: Software executable wasnt found in the specified path.
Operation Failed. Please view the log for more details.
Cause:
=====
If the domain hawkagent is not running then the domainutilitycmd is not able to verify / retreive EMS installation details. As a result it fails with the above mentioned error.
Resolution:
==========
To resolve this issue:
1). Make sure the EMS executable path is correct in the AddJMSServer.xml file.
2). Check if the domain hawkagent is running.
References:
==========