Description:
Symptom:
------------
When the connection parameters (User Name and Password) for the adapter design-time connection are specified as Global Variables, adapter throws below connection error.
AEADSBL-400035 Connection to Siebel Repository failed. [Startup Error.Unable to create a connection with the target application Siebel Server using connection parameters:userid = %%SiebeLoginName%%, Connect String = siebel.tcpip.none.zlib://. . . . . ., Language parameter= , application error : SBL-SEC-10018: You have entered an invalid setof logon parameters. Please type in your logon parameters again.(SBL-DAT-00446)]
Impact:
----------
Loss of functionality. This issue is particular to design time connection and works fine during the run time connection.
Workaround:
-----------------
Enter the value of User Name and Password under Design-time Connection tab instead of Global Variables.
Resolution:
--------------
The issue has been addressed in TIBCO Adapter for Siebel 5.3.1.