Products | Versions |
---|---|
TIBCO BusinessEvents Enterprise Edition | - |
Not Applicable | - |
Description:
Defect BE-17928 is fixed in TIBCO BusinessEvents 5.1.1 GA release.
Description:
============
Defect BE-17928 is fixed in TIBCO BusinessEvents 5.1.1 GA release.
Environment:
==========
o TIBCO BusinessEvents (BE) release 5.1.1 GA.
o All Operating Systems.
Symptoms:
=========
A rule function configured in the shutdown function of the CDD file was not called when the engine was stopped or killed from TIBCO Administrator.
Cause:
=====
This is a defect in Prior BE 5.x releases.
Resolution:
=========
This issue is now fixed in TIBCO BusinessEvents 5.1.1 release and it is available for download from https://download.tibco.com/tibco/