How do I change Error Reporting Limit in BusinessConnect for EDI documents ?

How do I change Error Reporting Limit in BusinessConnect for EDI documents ?

book

Article ID: KB0092346

calendar_today

Updated On:

Products Versions
TIBCO BusinessConnect EDI Protocol Powered by Instream -
Not Applicable -

Description

Resolution:
If BC-EDI is throwing the following error while processing EDI documents
--
Category:  Rejecting
Severity:  Normal
Brief:  : Error reporting limit exceeded. [ID=0xA10024]
Details:  Analysis halted after 101 error(s) (Limit for EntireDocument is 100)
--
You can change the Error Reporting Limit by following these steps:


(1) Go to  "&ltBC-HOME>\protocols\edi\tpcl\config" directory.
(2) Open file "XERegistry.xml" in any editor.
(3) Look for &ltCategory Name="ErrorLimit"> and change the appropriate Interchange, Group, Transaction, or EntireDocument limit as appropriate.
(4) Save the document.
(4) Restart your BC Engine for above change to take effect.

If you are migrating from BusinessConnect EDI 2.8 to BusinessConnect EDI 5.1 or EDI 5.2 release, we recommend using same value which was set in "&ltBC-HOME>\EDI\config\registryValidator.xml" (For BC-EDI 2.8).

Issue/Introduction