Products | Versions |
---|---|
TIBCO iProcess Analytics Export | - |
Not Applicable | - |
Resolution:
SPMExport could not be started. The error shows the error:
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [E] Application-defined or object-defined error
Complete logfile:
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] Checking logging path...
10/10/2007 18:14:25 [M] Logging mode OK.
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] Logging mode OK.
10/10/2007 18:14:25 [M] Checking repositories . . .
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] Checking repositories . . .
10/10/2007 18:14:25 [M] Repositories OK.
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] Repositories OK.
10/10/2007 18:14:25 [M] Checking export mode . . .
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] Checking export mode . . .
10/10/2007 18:14:25 [M] Export mode OK.
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] Export mode OK.
10/10/2007 18:14:25 [M] Checking SPO COM client . . .
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] Checking SPO COM client . . .
10/10/2007 18:14:25 [M] Connecting to SPO COM Client . . .
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] Connecting to SPO COM Client . . .
10/10/2007 18:14:25 [M] Connection to SPO COM Client established.
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] Connection to SPO COM Client established.
10/10/2007 18:14:25 [M] SPO COM client found.
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] SPO COM client found.
10/10/2007 18:14:25 [M] Starting Converter...
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [M] Starting Converter...
10/10/2007 18:14:25 [E] Application-defined or object-defined error
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [E] Application-defined or object-defined error
10/10/2007 18:14:25 [E] Error during conversion. The conversion has been aborted.
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [E] Error during conversion. The conversion has been aborted.
10/10/2007 18:14:25 [E] Error during conversion. The conversion has been aborted.
10/10/2007 18:14:25 [D] ZLogging:writeLogIntern: 10/10/2007 18:14:25 [E] Error during conversion. The conversion has been aborted.
Most likely cause of corruption would be that the end tag for the profile element is missing or that there is an error somewhere in the swexport.xml file so that the end tag does not pair up with the profile element.
This could happen if the swexport.xml file is edited manually. If there is a missing quote (“) symbol, this would cause the problem. If any of the “node” elements do not have a valid end tag, this would also cause the problem.
Solution:
correct/replace swexport.xml file the utility uses (defined in registry string HKEY_LOCAL_MACHINE\SOFTWARE\Staffware plc\SPM Export\AppPath) with a valid XML format