TIBCO ActiveMatrix Adapter for Files for Unix/Win(FA)service fails with the error,"AEFA-000033 No formating defined for class.

TIBCO ActiveMatrix Adapter for Files for Unix/Win(FA)service fails with the error,"AEFA-000033 No formating defined for class.

book

Article ID: KB0092842

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Files for Unix and Windows -
Not Applicable -

Description

Description:

While trying to run TIBCO ActiveMatrix Adapter for Files for Unix/Win (FA) Tester, it fails with the following error.

"AEFA-000033 No formating defined for class , the Position from Header attribute setting for the child records should be either begin or end,and it cannot be in null. "

Symptoms:
When trying to start File Adapter tester, it fails with the error, "AEFA-000033 No formating defined for class , the Position from Header attribute setting for the child records should be either begin or end,and it cannot be in null."
Cause:
This is a project specific issue that is caused while the project is upgraded from file adapter version 6.2.1 to 7.0.0. It occurs as the schemas within the project are not properly saved.

Environment

Product:TIBCO ActiveMatrix® Adapter for Files for Unix/WinVersion: 7.0.0OS:All Supported Operating Systems--------------------

Resolution

To resolve this issue, follow the steps below. 

For each process/schema in the project

1). Remove the schema from the schema tab.
2). Edit the schema by adding one field and then revert the changes by removing the recently added field to make it as is. 
3). Add the schema in the process under the schema tab.

Follow the above steps for each process and then run the project.

Issue/Introduction

TIBCO ActiveMatrix Adapter for Files for Unix/Win(FA)service fails with the error,"AEFA-000033 No formating defined for class.