Resolution:
Description:
============
MQSeries applications fail with the "MOM_NO_MQSSTUB" exception.
Environment:
============
o any z/OS version of OSB
Symptoms:
=========
MQSeries applications fail with the "MOM_NO_MQSSTUB" exception.
Cause:
======
This exception means that the Batch MQSeries stub is not linkedited into the S6BDRSES/HRNDRSES load module. This is normally for 1 of 2 reasons.
1) The MQSeries usermod has not been installed.
2) The MQSeries usermod has been regressed by application of SMP maintenance to S6BDRSES.
Resolution:
===========
Increase the REWORK() level of the usermod, if it has been previously installed, and RECEIVE and APPLY the usermod.
References:
===========
TIBCO® Object Service Broker for z/OS Installing and Operating - Installing the Service Gateway for WMQ