Resolution:
To Configure EMS reconnectivity for Tibco Adapter for SAP.
We have two mechanisms to configure EMS reconnectivity, below follows the details of the same.
1) Mechanism1:
Usage of factories.conf file for Re-connectivity (to be used only when JNDI is enabled)
Please update the following changes to the Factories.conf file.
________________________________________________________________
[TopicConnectionFactory]
Type = topic
URL = tcp://< hostname>:7222, tcp://<hostname>:7222
Metric = connections
connect_attempt_count=10000
connect_attempt_delay=5000
reconnect_attempt_count=10000
reconnect_attempt_delay=5000
[QueueConnectionFactory]
Type = queue
URL = tcp://<hostname>:7222, tcp://<hostname>:7222
Metric = connections
connect_attempt_count=10000
connect_attempt_delay=5000
reconnect_attempt_count=10000
reconnect_attempt_delay=5000
Also, provide the JMS provideURL in the adapter tra in the following way:
tcp://< hostname>:7222, tcp://<hostname>:7222
2) Mechanism2:
Usage of adr3.tra file for Re-connectivity( can be used when JNDI is unchecked)
-------------------------------------------
a) Add two urls to JmsProviderUrl global variable in adr3.tra separated by a comma.
e.g. tibco.clientVar.JmsProviderUrl =tcp://<ems_server_name>:7222,tcp://<ems_server_name:7222
b) Add two variables as shown below to adr3.tra file. This will be referenced by adapter when it tries to reconnect to JMS server
tibco.jmsReconnectCount=10000
tibco.jmsReconnectDelay=5000
c) Go to "Connection Factory Name" field under all available JMS Sessions under "Advanced Folder" of Adapter configuration and make the value blank.
The value of tibco.jmsReconnectDelay above is in millisec