Description:
Both instances ran as active in Fault Tolerance EMSA appliances. What could cause this dual active situation?
Symptoms:
N/A
Cause:
EMSA appliance uses crosslink to send heartbeats and does replication
between EMS FT instances. However, the EMS server will not decide to go
ACTIVE-STANDALONE using the heartbeat only. It contacts the monitioring
agent when it detects a replication failure. The monitoring agents on
the two appliances heartbeat every second over all three links, Mgmt-IP,
EMS-IP and Crosslink-IP. Only when all three are lost will the peer
appliance be declared down causing a STANBY to transition to STANDALONE.
We have seen a users case that the nvOSd was restarted due to the EMS-IP and Crosslink-IP heartbeats being lost. This error does not affect the Mgmt-IP which is independent of nvOSd. However, in this case, the mgmt-IP was also disconnected at that time so this resulted in all three physical links being missing at the same time, leading to dual active EMS instances situation.