S0C4 in module HRNHLLTO followed by message HRNDR014E and shutdown of the Execution Environment or other unpredictable errors.

book

Article ID: KB0088351

calendar_today

Updated On:

Products Versions
TIBCO ObjectStar Integration Foundation -
Not Applicable -

Description

Resolution:
Description:  
Module HRNHLLTO incurs a storage violation resulting in abend S0C4 or other unpredictable results within an Execution Environment.

Environment:
Occurs infrequently within an Execution Environment address space running on z/OS.

TIBCO Products Affected:
TIBCO ObjectStar for z/OS 4.1.1 with PTFs AP11665 or AP11766 applied.


Symptoms:
Messages as may appear on Execution Environment JES log:
  IEA995I SYMPTOM DUMP OUTPUT
  SYSTEM COMPLETION CODE=0C4  REASON CODE=00000004
   TIME=13.37.33  SEQ=18679  CPU=0000  ASID=006C
   PSW AT TIME OF ERROR  078D0000   96C3AF06  ILC 4  INTC 04
     ACTIVE LOAD MODULE           ADDRESS=16C39C38  OFFSET=000012CE
     NAME=HRNHLLTO
     DATA AT PSW  16C3AF00 - B01C5040  10005040  208C0700
     GR 0: 00000008   1: 00000000
        2: 17FD7E30   3: 00000005
        4: 0000000D   5: 00000000
        6: 16C3AF40   7: 001E6918
        8: 00000000   9: 00000000
        A: 00007BB0   B: 31E38400
        C: 96C3AE98   D: 001E6FB8
        E: 00FD86F0   F: 16C3AFB6
   END OF SYMPTOM DUMP

Followed by:
   HRNDR014E EE main task TCB has been terminated prematurely due to the unrecoverable error.

Cause:
This error is caused by an error in HRNHLLTO error recovery ESTAE logic described by problem report CR 1-843NF3 and is corrected in TIBCO Object Service Broker for z/OS 5.0.0.


Resolution:
Upgrade to TIBCO Object Service Broker for z/OS 5.0.0.

References:
TIBCO problem report CR 1-843NF3.

Issue/Introduction

S0C4 in module HRNHLLTO followed by message HRNDR014E and shutdown of the Execution Environment or other unpredictable errors.