Description

Resolution:
Description:
============
After installing iProcess Insight 2.2, we find the process starter (such as File Poller) output is not available for input of subsequent steps in designer.

Environment:
===========
Tibco TRA:            5.6.1
Tibco BW:             5.7.1
Tibco iProcess Insight:  2.2

Symptoms:
========
When try to map the output of a process starter to subsequent activity, no output items can be found.

Cause:
=====
It should be a library loading issue. By default Tibco BusinessFactor (BF) 5.4.0 is shipped with iProcess Insight 2.2. BF related paths are added to designer.tra automatically and it may cause library conflicts.

Resolution:
==========
To workaround, please find the properties tibco.env.CUSTOM_CP_EXT and tibco.env.CUSTM_PALETTE_PATH in designer.tra and move all BF related paths to the end of the class path.