Command Line Switches For AX Company Not Applying To TIBCO Scribe® Insight DTS

Command Line Switches For AX Company Not Applying To TIBCO Scribe® Insight DTS

book

Article ID: KB0077987

calendar_today

Updated On:

Products Versions
TIBCO Scribe Insight 7.9.1, 7.9.2

Description

TIBCO Scribe® Insight can send records to more than one Microsoft Dynamics AX Company when processing records received in a Message Queue.

Queue-based integration using DTS Parameters command line switches is intermittently ignoring settings for specific Dynamics AX companies and using the default Dynamics AX company. (D9722 / Case # 7783)

 

Issue/Introduction

Queue-based integration using DTS Parameters command line switches is intermittently ignoring setting and using default AX company.

Resolution

Go to the target connection > DTS Connection Settings, and uncheck the Keep this connection open option.  This reduces adapter performance but should allow the messages to be processed properly.

kA232000000PDv9CAG_en_US_1_0


Note:  If unchecking the " Keep this connection open..." option does not resolve this issue, please contact TIBCO Scribe® Support for assistance and reference KB 40055:  Modify CMDTarget value to identify target connection for DTS Parameters

Additional Information

For additional information, see the following in the Scribe Insight Help: