How to configure IQC analysis with one side specification limit in Enterprise Manager?
book
Article ID: KB0080746
calendar_today
Updated On:
Products
Versions
Spotfire Statistica
13.0 and later
Description
This article shows how to configure the IQC analysis with one side specification limit, so that MAS only triggers alarm for samples outside of the one sided specification limit.
Resolution
1. During the data configuration, specify the single variable that contains specification limit(lower/upper) and do not specify other limits types.
2. During the IQC analysis configuration, under SPC Characteristics|Characteristics|Specifications, check "Do not calculate Control limits for the X-chart" and "Do not calculate control limits for the R-chart" on the bottom.
Issue/Introduction
How to configure IQC analysis with one side specification limit in Enterprise Manager?