Description

After installing the prerequisite Foresight products (Instream and Translator), the TIBCO BC EDI Protocol 6.7.0 installation fails to process EDI documents. Investigation reveals that the $dir.ini files were not properly created in the Foresight Instream / Translator installations

The installation order is:
1) Instream 3.5.0
2) Instream 3.5.0 HF05
3) Translator 3.5.0
4) Translator 3.5.0 HF04
5) BC 6.3.0
6) BC 6.3.0 HF02
7) BC EDI 6.7.0
8) BC EDI 6.7.0 HF01

Issue/Introduction

After installing the prerequisite Foresight products (Instream and Translator), the TIBCO BC EDI Protocol 6.7.0 installation fails to process EDI documents. Investigation reveals that the $dir.ini files were not properly created in the Foresight Instream / Translator installations

Environment

All

Resolution

This issue happens when you install just runtime and database. To resolve this issue, install all Instream and Translator components or manually create this file based upon the $dir.ini.template.

Additional Information

Foresight documentation.