Products | Versions |
---|---|
TIBCO Enterprise Message Service Appliance | 3.0.0 |
This hotfix addressed issue EMS-7155, which may cause the standby store file grow much larger than the corresponding store files of the active-replicating server. You could check the storefile sizes by using the diagnostic command ‘disk-check stores’. If the Standby store files that are significantly larger than the corresponding Active server storefile, please apply this hotfix.
This hotfix can be downloaded from the SFDC Customer Portal Web User Interface using your username and password for the TIBCO Support Web. Once logged on you can find the hotfix under the Downloads Menu:
"AvailableDownloads/Messaging/EMSA/3.0.0/TIB_emsa_3.0.0_HF-001_illumos11_x86_64.pkg. Please read the Readme file before to apply the hotfix.
This hotfix is also available for EMSA-2.5.1 at : "AvailableDownloads/Messaging/EMSA/2.5.1/TIB_emsa_2.5.1_HF-002_illumos11_x86_64.pkg"
Closed Issues in 3.0.0_HF-001 (This Release)
EMSA-1881
Fixed an issue where failure to create a mgmt-zone would cause the ems-gateway to not activate on boot.
EMS-7155
Fixed a defect in which the store files of an EMS server in standby-replicating state could grow much larger than the corresponding store files of the active-replicating server.
EMS-7296
Fixed a defect in which slow operations could interfere with the heartbeat protocol between the EMS server and clients, resulting in client disconnect. This defect affected Releases 2.4.0 to 3.0.0.