Using the TIBCO Scribe® Online Connector For ODBC to connect to an AS/400 table, the Scribe® Online connection tests successfully, but running a Solution results in the error below. The ODBC datasource is configured to use the Progress DataDirect DB2 Wire Protocol Driver.
SLSREL in TEST#FILE not valid for operation. 3
: Error in calling Operation Create
On the server hosting the on-premise agent, a test of the ODBC datasource using a SQL query tool returns the following error:
ERROR: [DataDirect][ODBC DB2 Wire Protocol driver][UDB DB2 for iSeries and AS/400]SLSREL in TEST#FILE not valid for operation. 3 Error Code: -7008
Default "Advanced" settings for the DB2 datasource