Description
We are getting CDC LogMiner adapter error with Oracle version 19c. Applications are working fine with Oracle 18c.
ORA-06512: at "SYS.DBMS_LOGMNR", line 72
ORA-06512: at line 1
]
java.sql.SQLException: ORA-44609: CONTINOUS_MINE is desupported for use with DBMS_LOGMNR.START_LOGMNR.
ORA-06512: at "SYS.DBMS_LOGMNR", line 72
ORA-06512: at line 1
Can you please help to confirm the compatibility of the CDC LogMiner adapters with Oracle 19c?
Resolution
The TIBCO Streaming CDC LogMiner adapters:
- Oracle CDC LogMiner Connection Adapter
- Oracle CDC LogMiner Parser Adapter
will not work in Oracle 19c.
Oracle states here:
https://docs.oracle.com/en/database/oracle/oracle-database/19/upgrd/behavior-changes-deprecated-desupport-oracle-database.html#GUID-4B922F38-109D-42DF-B2AD-698E9FD8A8DE"The continuous_mine option for the dbms_logmnr.start_logmnr package is desupported in Oracle Database 19c, and is no longer available. The continuous_mine functionality of the LogMiner package is obsolete. It was deprecated in Oracle Database 12c Release 2 (12.2). There is no replacement functionality."
Some alternatives available when using TIBCO Streaming are:
- send to Streaming directly from the systems supplying data into Oracle,
- poll the tables with a regular JDBC Query Read operator for changes from the last polled timestamp,
- create an Oracle trigger on each table that uses Java and the Streaming Java Client API to enqueue changes to Streaming via an Input Stream
Issue/Introduction
3rd-Party Functionality Change