You can download this HotFix from TIBCO Support Portal (https://support.tibco.com). You will need to provide your TIBCO Support Portal credentials. Once logged in you can the download the hotfix by selecting the “Downloads” -> “Hotfixes” option. Then go to the AvailableDownloads/BusinessWorks/6.7.0/hotfix-01.
================================================================================ Closed Issues in 6.7.0_HF-001 (This Release)
AMBW-42534 After renaming a process package, the Input tab of the Call Process activity is not displayed.
AMBW-42418 The BW.MODULE.NAME and BW.MODULE.VERSION module properties return empty values.
AMBW-42416 On stopping an application, the application cannot call the delete method of the shared resource when the shared resource uses a module property in one of the fields.
AMBW-42344 The Write File activity cannot generate a file when the TextContent field has the space character (" ") value.
AMBW-42212 An application becomes unresponsive on the Send Mail activity and does not timeout when the existing engine threads are occupied.
AMBW-42125 TIBCO Business Studio for BusinessWorks displays an error message for the OAuth Configuration shared resource when the confidentiality is not defined for the HTTPS.
AMBW-42099 The operationID field is now displayed in the runtime Swagger file of a REST service when it is hit from Swagger UI.
AMBW-42086 After Tibtunnel recovers from its termination, TIBCO ActiveMatrix BusinessWorks cannot connect to the on-premise resources such as Enterprise Message Service (EMS) for the one round of Timer trigger.
AMBW-42068 The CurrentElement of the Iterate Group is not populated and the element remains empty.
AMBW-42048 The BWAgent's query working with TEA uses bind variables in the query on the Oracle database.
AMBW-42045 The Use local time check box is added on the General tab of the Timer activity. If you select the check box, the timer is triggered at the specified Start Time value of the container's time zone.
AMBW-41954 Now module property is supported for the following fields of the OAuth Configuration shared resource:
AMBW-41718 When you manually map an element through the suggestive mapping, the Mapping Score % value in the Recommended Mappings dialog box is set to 100%.
AMBW-41099 The Last Modified date of an API in the API Explorer tab is incorrect.
AMBW-40159 Modifications done inside a running application in TIBCO Business Studio for BusinessWorks displays the "Process not found" error.
AMBW-38327 Request with CDATA tags can now be sent with SOAP Invoke activity. For the CDATA tags to remain intact on the wire we need to set the below java property in VM arguments : bw.binding.soap.invoke.cdata.serialization=true
AMBW-35328 The Configure Local Swagger option does not work when you import a project in TIBCO Business Studio for BusinessWorks first and then configure the Local Folder path in the API explorer tab.