TIBCO ActiveMatrix(R) Adapter for Database 7.2.0 Hotfix 7 is now available

TIBCO ActiveMatrix(R) Adapter for Database 7.2.0 Hotfix 7 is now available

book

Article ID: KB0079536

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Database 7.2.0

Description

TIBCO ActiveMatrix Adapter for Database 7.2.0 Hotfix 7 is released for all platforms. Please refer to the product Readme file for details regarding the supported platforms. 

Listed below is a summary of updates included in this Hotfix. Please refer to the Hotfix Readme for additional details and installation instructions.
================================================================================
Closed Issues in 7.2.0_HF-007 (This Release)

AADB-7735
When using RPC mode of the ADB server, the runtime engine throws JMS error:  "Message not delivered when reply message to RPC standard invoker". 

AADB-7707    
ADB adapter 7.2 HF6 installation has issue as the environment variable "tibco.env.CUSTOM_CP_EXT" in the adbagent.tra file is getting changed after installation

AADB-7703    
TimeStamp issue when receiving transactions from Database using ADB

Configuration Instruction:
To keep the zero milli second of datetime field value in the publish messages, 
please add following tra property with value of "on" (default value is "off")
adb.keepZeroMilliSecond on
When it is on, the output of datetime field is like "2018-09-06 01:59:23.0"; 
while it is off, the value is like "2018-08-28 06:16:22".

AADB-7698    
ADB Adapter does not show nano seconds as a part of DateTime 
Float and Double datatypes support only scientific notation

Configuration Instruction: 
To have nano seconds data as part of datetime field value of publish messages, 
please add following tra property with value of "on" (default value is "off"),
adb.pubTimestampWithNanoSeconds on
The expected datetime field value is like "2018-09-06 2018 00:00:00.123000000". 
Except when there is no time is presented in original value. e.g., 
"2018-09-06 00:00:00", then there will be no nano seconds added. 

To have float and double datatypes without scientific notation as part of  publish messages, please add following tra property with value of "on" (default  value is "off"),
adb.noFloatDoubleScientificNotation on
If the input data is in scientific format, like 6.743240136E-7, then it will be converted to non scientific format like 0.000000674324014

AADB-7687    
Published messages have different timestamp format for parent table and child table

AADB-7682    
ADB adapter throws an exception when joining parent-child table using the date field
================================================================================

This hotfix can be downloaded from TIBCO Support Customer Portal Web UI(https://support.tibco.com). You will need to provide your TIBCO Support Portal credentials. Once logged in you can download the hotfix by selecting the “Downloads” -> “Hotfixes” option under:

/AvailableDownloads/Adapters/ActiveDataBase/7.2.0/hotfix-07

Please contact TIBCO Support if you have any problems finding or downloading this Hotfix.

Issue/Introduction

TIBCO ActiveMatrix(R) Adapter for Database 7.2.0 Hotfix 7 is now available

Environment

Product: TIBCO Adapter for ActiveDatabase Version: 7.2.0 OS: All Supported Operating Systems

Additional Information

TIBCO ActiveMatrix(R) Adapter for Database 7.2.0 , ADB Adapter 7.2 Hotfix 7

Attachments

TIBCO ActiveMatrix(R) Adapter for Database 7.2.0 Hotfix 7 is now available get_app