TIBCO BusinessConnect EDI Protocol powered by Instream 6.8.0 hotfix 1 has been released

TIBCO BusinessConnect EDI Protocol powered by Instream 6.8.0 hotfix 1 has been released

book

Article ID: KB0102049

calendar_today

Updated On:

Products Versions
TIBCO BusinessConnect EDI Protocol Powered by Instream 6.8.0

Description

TTIBCO BusinessConnect EDI Protocol powered by Instream 6.8.0 hotfix 1 has been released.

You can download this Hot Fix from the TIBCO Product Support website using your TIBCO Support username (email address) and password under “Downloads” and then “Hotfixes”

Once you have successfully logged into the server, you will find the hotfix packages under

           /AvailableDownloads/BusinessConnect/EDI/6.8.0/hotfix-01

Listed below is a summary of updates included. Please refer to the associated readme document for any additional information.

================================================================================
Closed Issues in 6.8.0_HF-001 (This Release)

EDIP-2809
When generating outbound ack from TIBCO BusinessConnect for an inbound request
group and interchange header values are generating from Tp configuration 
instead of values from incoming request. In this release we have added a flag 
that enables/disables outbound ack creation from TP settings to an inbound request.

Add the following boolean properties to BusinessConnect > 
System Settings > Activated Protocol Plug-ins and Properties > tibEDI.

--edi.x12.outbound.ack.creation.fromTP: Enabling this property will override 
the interchange and group header details for an outbound ack from TP configuration 
for X12 protocol.
--edi.edifact.outbound.ack.creation.fromTP: Enabling this property will override 
the interchange and group header details for an outbound ack from TP configuration 
for EDIFACT protocol
Note: The default value of these properties is set to TRUE, i.e., it will get the values 
from TP configuration for ack creation.

EDIP-2755/EDIP-2758
When inbound validation and EDI to XML conversion are disabled, 
RESPONDER.REQUEST message from PP is having and sourceFile property is empty.
This issue is fixed in this release.

EDIP-2813
Inbound EDI-X12 documents with multiple interchanges are moved to Error 
Directory by gateway server

EDIP-2814
BusinessConnect fails to parse file if the inbound EDI
document contain unknown TP.NullPointerExceptions are getting logged.

EDIP-2815
TIBCO BusinessConnect EDI Protocol powered by Instream is dropping EDI 
transactions in translation.

EDIP-2816
TIBCO BusinessConnect EDI Protocol powered by Instream Outbound File Poller 
transport failures are not moving the file to error directory.

EDIP-2817
Inbound EDI files from Gateway partner are archived under both Gateway and X12.

EDIP-2819
CAQH-Status is shown incorrectly for 824 transaction when performing 
scheduled transmission

Issue/Introduction

TIBCO BusinessConnect EDI Protocol powered by Instream 6.8.0 hotfix 1 has been released

Environment

all platforms