TIBCO Managed File Transfer Platform Server for z/OS 8.0.0 hotfix HF-005 is now available

TIBCO Managed File Transfer Platform Server for z/OS 8.0.0 hotfix HF-005 is now available

book

Article ID: KB0101885

calendar_today

Updated On:

Products Versions
TIBCO Managed File Transfer Platform Server for zOS 8.0.0

Description

Hotfix TIB_mftps-zos_8.0.0-HF-005 can be downloaded from TIBCO Support Portal (https://support.tibco.com).  
 
You will need to provide your TIBCO Support Portal credentials.  Once logged in you can download the hotfix by selecting the “Downloads” -> “Hotfixes” option. Then go to “/AvailableDownloads/MFT/PlatformServer/zOS/8.0.0/hotfix-05” to download the hotfix.
 
The .zip file has the Readme file inside. Please unzip the file and review the Readme file for instructions on how to apply the hotfix.
 
Problem Description:
This hotfix resolves defects that have been fixed since V8.0.0 was
released.
 
================================================================================
Defects fixed in V800HF05 (This Release)
 
PSZ-361 CPU Loop occurred when sending RECFM=VBS file with
        MAINTAINBDW=BLOCKVS to a tape file that already exists
PSZ-360 PGTVERSN utility does not display hotfix level
PSZ-359 When Command Center initiates a directory transfer defined with
        StopOnFailure=No, the transfer stops after the first failed
        transfer.
PSZ-356 Abend 102 received when ISPF user deletes a transfer queued in the
        MFT Started task with the EVERY parameter ================================================================================
Defects fixed in V800HF04
 
PSZ-354 Abend 0C4 received in FUSFIPS0 when using SSL mode on new Z Series
        hardware
PSZ-352 FUSUTIL received an abend 0C4 when deleting a migrated dataset
================================================================================
Defects fixed in V800HF03
 
PSZ-346 Messages file does not include all messages added to V8.0.0
================================================================================
Defects fixed in V800HF02
 
PSZ-345 When an LBI tape file was created with RECFM=U, the BLKSIZE on the
        tape label was set to 0
PSZ-341 Abend 0C4 occurred at FUSASEND+A10 when sending a PDS with an alias
PSZ-340 Transfer of LBI dataset does not maintain blocksize when
        RECFM=FB or VB
PSZ-339 The Started task will go into loop when sending an LBI file from
        z/OS to z/OS when MAINTAINRDW or MAINTAINBDW is set
PSZ-338 Intermittent Abend 0C4 in FUSIONIO+149E0 when a send transfer was
        restarted and the local file RECFM=U
PSZ-337 ISPF Requests using TCP IPName FUSCFG configuration display
        message PGTT1761I
 ================================================================================
Defects fixed in V800HF01
 
PSZ-336 When Command Center initiated a transfer, message "PGTS2432I"
        was incorrectly returned instead of the file transfer message
PSZ-335 SSL Negotiation failed when TLSCIPHERS are not defined in the
        GLOBAL
PSZ-334 Intermittent abend 0C4 in OSINBDAP+ED4
PSZ-333 Command Center Initiated transfers truncated the Responder IPName
        after 24 bytes
================================================================================

Issue/Introduction

TIBCO Managed File Transfer Platform Server for z/OS 8.0.0 hotfix HF-005 is now available

Environment

All supported environments