TIBCO Managed File Transfer Platform Server for z/OS 8.1.0 hotfix HF-004 is now available
book
Article ID: KB0100474
calendar_today
Updated On:
Products
Versions
TIBCO Managed File Transfer Platform Server for zOS
8.1.0
Description
This hotfix resolves defects that have been fixed since V8.1.0 was released.
Environment
All supported environments
Resolution
Hotfix TIB_mftps-zos_8.1.0-HF-004 can be downloaded from TIBCO Support Portal (https://support.tibco.com).
You will need to provide your TIBCO Support Portal credentials. Once logged in you can download the hotfix by selecting the “Downloads” -> “Hotfixes” option. Then go to “/AvailableDownloads/MFT/PlatformServer/zOS/8.1.0/hotfix-04” to download the hotfix.
The .zip file has the Readme file inside. Please unzip the file and review the Readme file for instructions on how to apply the hotfix.
================================================================================ Defects fixed in V810HF04 (This Release)
PSZ-502 When many transfers complete at the same time, some transfers are not returned to the Command Center Collector PSZ-499 The Batch interface receives "Connect Timeout" errors when using TCP to schedule a transfer with the started task Note: Three new FUSCFG parameters have been added to support retries when the schedule request fails with a CONNECT error: CONNECTTIMEOUT=30 TCP CONNECT Timeout (10-255 seconds) CONNECTFAILUREWAIT=30 Wait between failed CONNECT (1-255 seconds) CONNECTTRIES=1 Number of CONNECT tries (1-255) Note: This hotfix must be installed on all interfaces (ISPF, REXX, BATCH) before the FUSCFG enry is updated; otherwise requests will fail. ================================================================================ Defects fixed in V810HF03 PSZ-494 When using ZLIB to compress uncompressible files, transfers may fail with error: "received data length 5FB612FF longer than Max Req. 7FF8" or "Invalid LU6.2 GDS received"
================================================================================ Defects fixed in V810HF02 PSZ-488 When GLOBAL ENFORCE_SECURITY_POLICY is set to FIPS140, message PGTS0029I is displayed and SNA initialization can be bypassed PSZ-487 When initiating a small file transfer to Internet Server and the transfer fails due to an Internet Server error, the transfer fails with a network error and the node definition is put into an error state PSZ-485 Responder File Deallocation is performed after the transfer ends and can cause allocation problems with third party software Note: A new Global parameter was added: DEALLOCATE=CLOSE|ENDOFTRANSFER (Defalt: ENDOFTRANSFER) PSZ-480 When the Global or Node definition specifies a default encryption, TLS TUNNEL initiated transfers receive error: "PGTM7219E Invalid Password exceeds max length 8" PSZ-479 The output dataset always uses the volume count of the input dataset Note: A new Batch parameter was added: VOLCT=nnn or VOLUMECOUNT=nnn
================================================================================ Defects fixed in V810HF01 PSZ-483 FUSUTIL Request failed when deleting a tape dataset Note: A new option has been added to the FUSUTIL command: TUNCAT Example: FUSUTIL TUNCAT mvs.dataset.name