TIBCO Substation ES 2.10.0 HotFix #1(revised) is now available.

TIBCO Substation ES 2.10.0 HotFix #1(revised) is now available.

book

Article ID: KB0102563

calendar_today

Updated On:

Products Versions
TIBCO Substation ES 2.10.0

Description


Hotfixes are cumulative. This is the first hotfix for Substation ES 2.10.0.

You can download Hotfix #1 from the TIBCO Support Customer Portal Web UI (https://support.tibco.com).
Log in using your username and password for the TIBCO Support Web page. 

  Select Download
  Select Hotfixes
  Select AvailableDownloads
  Select Mainframe
  Select Substation
  Select 2.10.0
  Select hotfix-1

You should then be able to see and download the files.

TIB_substation_2.10.0_zos.sxs.hotfix_#1.zip

TIB_substation_2.10.0_readme_hotfix.txt

Please note: Non-DFSMSdss installation packages are available by request only.

Listed below is a summary of updates included. Please refer to the associated readme document for any additional information.

================================================================================
Closed Issues in 2.10.0 hotfix#1 (This Release)

  

  SSES-1192 - High

  Buffer size gets evaluated incorrectly for Containers when BufferSize=M.
  When Recipe Service is set as MOI = 10, and the BufferSize = M for a
  conversion Rule, Substation was not recognizing the condition and was
  only using the buffersize and not the message size.
  This has been corrected.


  SSES-1191 - High

  When a RVDQ ESB interface includes workers and the BES goes down or services
  are suspended then other Substations in the same DQ group will not process
  any messages. This has been corrected.
  Note: An ESB interface where the RVDQ Scheduler is specified MUST have a 
        RVDQ workers value of zero then this interface will ignore operational
        commands such as Suspend, Unload and Disable.
        This will allow other address spaces sharing the same DQ group to 
        remain operational.   
  

  SSES-1189
    
  The ESB interface produces an inconsistent error when reconnecting to
  the EMS server after the initial connection process. 
  Amended the EMS ESB logical connection recovery to resolve this.
  

  SSES-1184
    
  Fixed the display order of the message 'SXA2666I End-of-Command'. 

  
  SSES-1181 - High
     
  In order to prevent the CICS Request/Reply processes running out of sessions.
  It is required to manually to update the CICS CSD for TRANClass (SXCTCL11),
  on the parameter Purgethresh from 1 to 2.
  This is required for Substation ES v2.9.0 and v2.10.0.


  SSES-1175 - Normal
  
  Operational commands now have and End-of-Command message to denote
  the end of output for a partiucular command.
  This now allows tools to easily determine the last message line.


  SSES-1171 - Normal 
  
  When Substation outputs a buffer and the field definition is "STRING",
  (null terminated), and the data does not end with a null, data overflow
  can occur as the correct data length would be incorrect. This is valid for
  both outbound and trigger data where the output message or field option is
  a string.
  This issue has now been resolved.


  SSES-1170 - Normal
  
  Triggers (TSQ) randomly takes more than 8 seconds of latency pulling
  messages from CICS. When the max record count wraps there could be
  possible delays depending on workload and counter numbers.
  This has now been fixed.

 

Issue/Introduction

TIBCO Substation ES 2.10.0 HotFix #1(revised) is now available.