TIBCO Substation ES 2.13.0 HotFix #2 is now available
book
Article ID: KB0076165
calendar_today
Updated On:
Products
Versions
TIBCO Substation ES
2.13.0
Description
You can download Hotfix #2 from the TIBCO Support Customer Portal Web UI (https://support.tibco.com). Log in using your username and password for the TIBCO Support Web page.
You should then be able to see and download the files. TIB_substation_2.13.0_zos.sxs.hotfix_#2.zip TIB_substation_2.13.0_readme_hotfix.txt
Please note: Non-DFSMSdss installation packages are available by request only. Listed below is a summary of updates included. Please refer to the associated readme document for any additional information.
Closed issues in Hotfix #2:
SSES-1941 - Critical
When using MOR-0 recipes, UoW will not be reused. An issue when normally doing a CICS / IMS recipe that has a MOR of 0, will encounter this issue. This issue has now been resolved.
SSES-1940 - RV High
Potentially you may experience high CPU usage when using RV Vectors and not providing the correct LE User Options. We have now provided an option where you can switch back using the standard RV dispatcher queue input. VECTORS-YN = Y will use the vectors. The default is Y (Yes). Issue is resolved.
Issue/Introduction
TIBCO Substation ES 2.13.0 HotFix #2 is now available.
Environment
z/OS 2.1 through z/OS 2.4
Resolution
Install Hotfix #2.