The TIBCO ActiveMatrix BusinessWorks(TM) 6.3.2 upgrade on existing BW 6.3.1 fails with P2 provisioning error.

The TIBCO ActiveMatrix BusinessWorks(TM) 6.3.2 upgrade on existing BW 6.3.1 fails with P2 provisioning error.

book

Article ID: KB0084307

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for sFTP -
Not Applicable -

Description

The TIBCO ActiveMatrix BusinessWorks(TM) 6.3.2 upgrade on existing TIBCO ActiveMatrix BusinessWorks(TM) 6.3.1 fails given that TIBCO ActiveMatrix BusinessWorks™ Plug-in for sFTP 6.1.0 is installed.
----
1) Install BW 6.3.1
2) Install BW plugin for sFTP 6.1.0
3) Install BW 6.3.2

Result: It fails with P2 provisioning error.
----
Following error message during upgrade:
----
   [java] Installation failed.
   [java] Cannot complete the install because of a conflicting dependency.
   [java] Software being installed: TIBCO ActiveMatrix BusinessWorks Design Feature 6.3.200.002   (com.tibco.bw.enterprise.design.feature.feature.group 6.3.200.002)
   [java] Software currently installed: TIBCO ActiveMatrix BusinessWorks Tools Feature 6.3.100.003 (com.tibco.bw.tools.feature.feature.group 6.3.100.003)
   [java] Only one of the following can be installed at once:
   [java] Business Works Migration API 6.3.200.001 (com.tibco.bw.migration 6.3.200.001)
   [java] Business Works Migration API 6.3.100.003 (com.tibco.bw.migration 6.3.100.003)
----
 

Issue/Introduction

The TIBCO ActiveMatrix BusinessWorks(TM) 6.3.2 upgrade on existing BW 6.3.1 fails with P2 provisioning error.

Environment

TIBCO ActiveMatrix BusinessWorks 6.3.1 TIBCO ActiveMatrix BusinessWorks 6.3.2 TIBCO ActiveMatrix BusinessWorks™ Plug-in for sFTP 6.1.0

Resolution

That is because sFTP plugin does p2 provisioning for "com.tibco.bw.tools.feature.feature.group" and mismatching of the libraries.

Install TIBCO ActiveMatrix BusinessWorks™ Plug-in for sFTP 6.1.1 before upgrading from BW 6.3.1 in which ‘p2 provisioning error’ has been fixed.