When I create a new File Adapter Configuration why are the service and daemon parameters set to 7474 and tcp:7474 respectively for the sessions DefaultRVSession and DefaultRPCSession?

When I create a new File Adapter Configuration why are the service and daemon parameters set to 7474 and tcp:7474 respectively for the sessions DefaultRVSession and DefaultRPCSession?

book

Article ID: KB0088997

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Files for Unix and Windows -
Not Applicable -

Description

Resolution:
You also get the same problem is you change the Quality of Service from reliable to Certified. However, if you create a new session using drag n' drop, the correct default global variables for the daemon and service show up.

The workaround is to always check the service and daemon parameters for all yours sessions and change them to the appropriate global variable where necessary (%%RvDaemon%% or %% RvService).

Issue/Introduction

When I create a new File Adapter Configuration why are the service and daemon parameters set to 7474 and tcp:7474 respectively for the sessions DefaultRVSession and DefaultRPCSession?