When the TIBCO Adapter for Files v4.1.0-02 is installed, and only "Design-Time Components" is selected, the corresponding DTA Windows service fails to start, because it does not create the required log file.

When the TIBCO Adapter for Files v4.1.0-02 is installed, and only "Design-Time Components" is selected, the corresponding DTA Windows service fails to start, because it does not create the required log file.

book

Article ID: KB0088992

calendar_today

Updated On:

Products Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Files for Unix and Windows -
Not Applicable -

Description

Resolution:
The Installer does not create one of the required directories when you choose to install only the ‘Design-Time Components’, therefore you must manually add the ‘logs’ directory (e.g. C:\TIBCO\Adapter\adfiles\4.1\logs, the DTA will then start without any problems. Further, if both the "Run-Time" and "Design-Time" components are installed the "logs" directory does exist and everything is fine.

Issue/Introduction

When the TIBCO Adapter for Files v4.1.0-02 is installed, and only "Design-Time Components" is selected, the corresponding DTA Windows service fails to start, because it does not create the required log file.