Why are we getting the error "XEngine: Failed Guideline" when BC-EDI is validating an incoming EDI file

Why are we getting the error "XEngine: Failed Guideline" when BC-EDI is validating an incoming EDI file

book

Article ID: KB0089101

calendar_today

Updated On:

Products Versions
TIBCO BusinessConnect EDI Protocol Powered by Instream -
Not Applicable -

Description

Resolution:
The reason could be the incompatibility between the tgl files
created for older versions of EDI protocol. For example, EDI1.5.0 tgl
files are not compatible with EDI2.0.0. Also, tgl files are platform
specific. If a tgl file has been created on Solaris, it cannot
be loaded into a EDI instance running on Windows OS. Both of the
above conditions will result in "XEngine: Failed Guideline" error.

Issue/Introduction

Why are we getting the error "XEngine: Failed Guideline" when BC-EDI is validating an incoming EDI file