Why does the HTTP agent using BW time out when started from command line?
book
Article ID: KB0085617
calendar_today
Updated On:
Products
Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for Siebel
-
Not Applicable
-
Description
Resolution: The cause of this behaviour could be incorrect configuration on HTTP Agent. Make sure you are using the correct .tra file while starting the HTTP Agent from command line. For the adapter and HTTP Agent to communicate with each other, the AgentPublisherSubject and AgentPublisherCMQ in the Agent's .tra file should be same as the subject and CMQ name of AgentRPCServer endpoint in the adapter configuration.
Please verify these parameters in your adapter configuration and the .tra file you are using while starting the HTTP Agent from command line. Please refer to the section 'Configuring the HTTP Agent' in chapter 13 'Configuring and Running the HTTP Agent using TIBCO BusinessWorks' of the user guide for details on Configuring and running the HTTP Agent for Business Works.
Issue/Introduction
Why does the HTTP agent using BW time out when started from command line?