The Adapter tester will not start when the project is opened via XML Canon.

The Adapter tester will not start when the project is opened via XML Canon.

book

Article ID: KB0087291

calendar_today

Updated On:

Products Versions
TIBCO Designer -
Not Applicable -

Description

Description:
Symptoms
========
The adapter tester will not start when the project is opened via XML Canon.  It will throw error as below:
Caused by: com.tibco.objectrepo.OperationFailedException: Could not determine path for http://tibco:6080/ARC-HandsOn/ as
http://tibco:6080/ARC-HandsOn/:  java.io.IOException: The filename, directory name, or volume label syntax is incorrect .

Impact
======
Loss of functionality.

Workaround
==========
Open the Project via XML Canon using designer and save to a local multifile project and then run the tester.

Cause
=====
There was a defect in Designer Adapter Tester.

Resolution
==========
Fixed in the next release (5.1.3).
Symptoms:

Cause:

Issue/Introduction

The Adapter tester will not start when the project is opened via XML Canon.