TIBCO Adapter for Teradata 5.2.0 supports TRA 5.2.0 and 5.2.1 and TIBCO BusinessWorks 5.2.0 and 5.2.1.
book
Article ID: KB0087118
calendar_today
Updated On:
Products
Versions
TIBCO Adapter for Teradata
-
Not Applicable
-
Description
Description: TIBCO Adapter for Teradata now supports TRA 5.2.0 and 5.2.1 and BusinessWorks 5.2.0 and 5.2.1, in addition to the currently supported TRA and BusinessWorks versions listed in the product documentation. The only TRA and BusinessWorks features supported by the adapter are those included in the documentation for TIBCO Adapter for Teradata.
No adapter configuration changes are required to use TRA 5.2.0 or 5.2.1 or BusinessWorks 5.2.0 or 5.2.1 with version 5.2.0 of the Teradata adapter.
Known Issues: ============= 1. BusinessWorks throws a serialization error for Custom RPC Invocation.
Symptoms: ========== When the user clicks on Input tab under Invoke an Adapter Request-Response Service activity of the BusinessWorks process, the schema contents will appear in red color denoting some error or expecting value for certain fields. In case of Custom RPC the BusinessWorks process should not expect a value as it is already specified in Teradata Server.
Impact: ======= When BusinessWorks process is started, it throws serialization error.
Workaround: ============ Please specify value for "MAXROWS' field as 0 which is the default value, under the input Tab of ‘Invoke an Adapter Request-Response Service’ activity.
Issue/Introduction
TIBCO Adapter for Teradata 5.2.0 supports TRA 5.2.0 and 5.2.1 and TIBCO BusinessWorks 5.2.0 and 5.2.1.