PeopleSoft Adapter 5.1.3 and 5.1.2 with Hotfix1 throws the error "class psft\pt8\pshttp\PSKeyStore not found exception" on receiving a request when used with PeopleTools 8.45
book
Article ID: KB0090270
calendar_today
Updated On:
Products
Versions
TIBCO ActiveMatrix BusinessWorks Plug-in for PeopleSoft
-
Not Applicable
-
Description
Description: Symptoms ======== If People Tools 8.45 version is used to run PeopleSoft adapter, it will throw an error class psft\pt8\pshttp\PSKeyStore not found exception on receiving a request. This problem can be seen when running the adapter instance with People Tools version 8.45 and User Profile CI or CI's created from User Profile CI are used.
Impact ====== Loss of functionality Adapter will not be able to complete processing of a message when using People Tools 8.45
Workaround ========== (see Resolution)
Cause ===== This is a PeopleSoft issue for the USER PROFILE with a specific People Tools version (8.45). For additional details, please refer to the PeopleSoft solution 200974612, "PeopleSoft Solution: Component Interface - PT 8.45x External APIs getting an error when trying to retrieve a second CI".
Resolution ========== PeopleSoft has provided the following resolution:
Please make a jar with the files present under the <PS_HOME>\<class folder> folder that comes with the PeopleSoft Server installation. PS_HOME is the installation folder of PeopleSoft and Class folder is the “class” folder exists under <PS_HOME>. Include it in the class path or place it in the lib folder of the adapter installation (<adapter_home>/5.1/lib).
Please refer to the PeopleSoft solution 200974612 for additional information on the resolution provided by Peoplesoft. Symptoms:
Cause:
Issue/Introduction
PeopleSoft Adapter 5.1.3 and 5.1.2 with Hotfix1 throws the error "class psft\pt8\pshttp\PSKeyStore not found exception" on receiving a request when used with PeopleTools 8.45